TroubleshootingGuide
8|Page
5.2TROUBLESHOOTING‐GENERALPROBLEMS
ProceedtotheErrorCodessectionifanerrorcodeisidentified.Forothercommonproblemsthatdo
notinvolveanerrorcode,seeifthefollowingitemshelp:
Thewaterisnothotenough.
Thewateristoohot.
Temperaturefluctuateswhenafixtureisopened.
Unitdoesnotignitewhenwatergoesthroughit.
Ittakesalongtimetogethotwateratthefixtures.
Thefanmotorisstillspinningafteroperationhasstopped.
Abnormalsoundscomefromtheunit.
Lossofpressureatallsinkswhenthedishwasher
fills.
Unithaspower,gas,andwaterbutdoesnotturnon.
MultipleHeaterSetup(Easy‐Link)
THEWATERISNOTHOTENOUGH
• Comparetheflowandtemperatureatthepressurereliefvalve.
o IfthetemperatureandflowratearecorrectatthePRVthentheproblemresidesinthe
plumbingline,notinthetanklessunit.Checkforacrossconnectionorotherwaterline
problems
• Testthehotwater
temperaturewithahandheldthermometertomeasurehowfaroffthewater
temperatureisfromthesettemperature.
o Thesettemperaturemaybesettoolow.Thetemperaturecanbechangedwiththe
pushbuttonsonthePCBorbytheremotetemperaturecontroller,ifoneisinstalled.
• Check
forcrossplumbingbetweencoldwaterlinesandhotwaterlines.SeetheProcedures
section(p.21)forinstructions.
• Unitmaybehardwaterscaled.Thescaleactsasaninsulatorpreventingtheheatexchanger
fromtransferringheattothewater.ContactaTakagiServiceAgent.
• Theunitmay
notbereceivingenoughgas.
o Thegassupplyvalvemaynotbefullyopen.
o Thegaslinemaybesizedimproperly.
o Thegassupplypressuremaybetoolow.Thismay becausedbyamalfunctioninggas
supplyregulator,sochecktoseeifyourregulatoris
workingproperly.
• Checktoseethatacheckvalveisinstalledbetweenthepumpdischargeandtheconnectionto
thecoldwatersupply.Inspectthecheckvalveforproperoperation.Ifthereisn’toneinstalled,
orifitismalfunctioning,coldwatermaybeback‐feedingintothesystem.
•
Double‐checkfora101errorcode.A101errorcodewillreducetheamountofgasinputinto
theheater.
• Outputtemperaturewillbeaffectedifairflowisimpeded.
o Checkconstructiondustanddebrisinventing,suchasdrywall.
o Ifthereisdustinside
thecabinet,therewillalsobedustinsidetheburnerandheat
exchanger.Seetheprocedureforcleaningtheburner(p.26).
THEWATERISTOOHOT
• Thesettemperaturemaybesettoohigh.Thetemperaturecanbechangedwithdipswitcheson
thePCBorbytheremotetemperaturecontroller,ifoneisinstalled.