48
TEMPERATURES MENU (CONT)
DESCRIPTION/ACTION DISPLAY
• Differential$GMXVWDEOHXVHUVHWWLQJWKDWFKDQJHVWKHWDQN
WHPSHUDWXUHGLIIHUHQWLDOZLWKDUDQJHRIWR)7KHIDFWRU\
VHWWLQJLV)
• Tank Temperature1RQDGMXVWDEOH&RQWUROV\VWHPVHQVHG
WHPSHUDWXUHDYHUDJHGIURPXSSHUORZHUWHPSHUDWXUHSUREHV
• Tank Probe OffsetDGMXVWDEOHXVHUVHWWLQJUDQJHWR
IDFWRU\VHWWLQJ
NOTE:7KHVHVHWWLQJVVKRXOGRQO\EHXVHGLIKRWZDWHUVXSSO\
WHPSHUDWXUHYDULHVJUHDWO\IURPWKH2SHUDWLQJ6HW3RLQWVHWWLQJ
7KH 7DQN 3UREH 2IIVHW LV XVHG WR FDOLEUDWH FRQWURO V\VWHP
WHPSHUDWXUH VHQVLQJ 7KLV FDQ LPSURYH WKH SUHFLVLRQ RI
WHPSHUDWXUHFRQWUROLQ WKHVWRUDJHWDQN DQGDWSRLQWVRIXVH
7KLV IHDWXUH FDQ DOVR EH XVHG WR FRPSHQVDWH IRU EXLOGLQJ
UHFLUFXODWLRQORRSVKRWZDWHUUHWXUQLQJWRWKHVWRUDJHWDQNWKDW
PD\FDXVHWKHKHDWLQJF\FOHVWRWHUPLQDWHSUHPDWXUHO\
([DPSOH,IWKHVHQVHGWHPSHUDWXUHIURPDWHPSHUDWXUHSUREH
LV) &DQG WKH2IIVHWVHWWLQJLVDGMXVWHGWR DYDOXH
RWKHU WKDQ WKH FRQWURO V\VWHP ZRXOG FDOLEUDWH RU ³RIIVHW´
WKH VHQVHG WHPSHUDWXUH IURP WKH SUREH DQG WKH DYHUDJHG
WDQN WHPSHUDWXUH +HDWLQJ F\FOHV ZRXOG EH DFWLYDWHG DQG
GHDFWLYDWHGEDVHGRQWKHFDOLEUDWHGRIIVHWWHPSHUDWXUH$
VHWWLQJUHVXOWVLQKRWWHUZDWHU
7KHVH VHWWLQJV DUH DGMXVWHG LQ WKH VDPH ZD\ GHVFULEHG IRU
2SHUDWLQJ6HW3RLQW$QG'LIIHUHQWLDO$GMXVWPHQWRQSDJH
Temperatures
HELPBACK
Operating Setpoint 120°F >
Differential 8°F >
Tank Temperature 120°F
Tank Probe Offset 0°F >
HEATER STATUS MENU
DESCRIPTION/ACTION DISPLAY
3UHVV +HDWHU 6WDWXV IURP WKH 0DLQ 0HQX WR HQWHU WKLV PHQX
7KLVPHQXFRQWDLQVQRQDGMXVWDEOHRSHUDWLRQDOLQIRUPDWLRQ8VH
WKHVOLGHEDUWRQDYLJDWHWKHPHQX
• StatusGLVSOD\VWKHFXUUHQW2SHUDWLQJ6WDWHVHH7DEOH
RQSDJH
• ECO ContactLow Gas PSBlocked Inlet PSBlocked
Outlet PSBlower Prover PSGLVSOD\VWKHFXUUHQWVWDWH
RIWKHVZLWFKFRQWDFWVRSHQRUFORVHG
• Igniter OnGas Valve OnGLVSOD\VZKHWKHURUQRWWKH
FRQWUROV\VWHPLVFXUUHQWO\HQHUJL]LQJWKHVHZDWHUKHDWHU
FRPSRQHQWV\HV HQHUJL]HGQR GHHQHUJL]HG
• Flame DetectedGLVSOD\VZKHWKHURUQRWWKHFRQWURO
V\VWHPKDVGHWHFWHG0DLQ%XUQHUÀDPHGXULQJLJQLWLRQIURP
WKHÀDPHVHQVRU
• Blower RPM CMD – GLVSOD\VWKHFRQWUROVFRPPDQGHG
EORZHUUSPV
Blower RPM – GLVSOD\VWKHDFWXDOEORZHUUSPV
• Anode Current, Anode Tank Voltage, Anode Drive
Voltage – GLVSOD\VWKHSRZHUHGDQRGHVFXUUHQWDQG
YROWDJHOHYHOV
NOTE: 0HQX GLVSOD\V VKRZQ DUH IRU LQIRUPDWLRQDO SXUSRVHV
RQO\7KH DFWXDOKHDWHU GLVSOD\ZLOO YDU\GHSHQGHQWXSRQ WKH
RSHUDWLRQDOVWDWHRIWKHZDWHUKHDWHU
7RSRI0HQX
Heater Status
HELPBACK
Status: Standby
ECO Contact Closed
Low Gas PS Closed
Blocked Inlet PS Closed
Blocked Outlet PS Closed
Igniter On No
0LGGOHRI0HQX
Heater Status
HELPBACK
Gas Valve On No
Flame Detected No
Blower RPM CMD 0
Blower RPM 0
Anode Current 51.500mA
Anode Tank Voltage 2.641V
%RWWRPRI0HQX
Heater Status
HELPBACK
Flame Detected No
Blower RPM CMD 0
Blower RPM 0
Anode Current 51.500mA
Anode Tank Voltage 2.641V
Anode Drive Voltage 3.539V