TR-069 Protocol Support
41-001373-01 REV02 – 05.2014 7
Configuring Periodic Inform Using the Configuration Files
Parameter –
tr69 periodic inform enable
Configuration Files aastra.cfg, mac.cfg
Description Enable or disable the periodic inform functionality.
Format Boolean
Default Value Empty
Range 0 - 1
0 (Disable)
1 (Enable)
Example tr69 periodic inform enable: true
Parameter –
tr69 periodic inform interval
Configuration Files aastra.cfg, mac.cfg
Description The duration in seconds of the interval for which the CPE must
attempt to connect with the ACES and call the inform method.
Format Integer
Default Value Empty
Range Not Applicable
Example tr69 periodic inform interval: 600
Parameter –
tr69 periodic inform time
Configuration Files aastra.cfg, mac.cfg
Description An absolute time reference in UTC to determine when the CPE will ini-
tiate the periodic inform method calls.
Format String
Default Value 1970-01-01T00:00:00
Range The STRING is specified in the following form: “YYYY-MM-
DDThh:mm:ss” where:
• YYYY (year)
• MM (month)
• DD (day)
• T (start of the required time section)
• hh (hour)
• mm (minute)
• ss (second)
Example tr69 periodic inform time: 0001-01-01T00:00:00