Technical Specifications
244
Note
The online help provides an overview of the limits that should be observed when
configuring the OpenCom 100.
Supply power 3 VA per U
pn
bus
Range 1,000 m
a/b ports
for analogue terminals with pulse or
DTMF dialling, flash duration of 60 to
310 ms
Possible interface cards:
–4 x a/b
–8 x a/b
–2 x S
0
and 6 x a/b
–Supply voltage 40V ± 10%
–Supply power 1.2VA
–Feed current 25mA
Range 1,000 m
V.24 port (COM)
for connection of a PC 1 x (optional)
–Range 3m
Doorstation equipment interface card
for connection of doorstation equip-
ment
1x (optional)
Contact load of actor 1.5 A / 125 V
Voltage range U
= 5V30V
Sensor Switched by low AC voltage
Voltage range U
~
= 6 V…24 V