8.3.4 Charging in a vehicle
1. Put the plug either into the socket on the battery pack or the so
-
cket on the s-max sella (please see chapter 8.3.2)
2. Then put the plug of the automatic charger into the 230 V
connector of the voltage converter.
3. Put the 12 V plug into the cigarette lighter.
4. Turn on the voltage converter by pushing the switch and the batte
-
ries are being charged.
A control light (LED) on the charger and a beeper in the voltage converter al
-
low the charging process to be monitored.
Signals of the charger and the voltage converter
8.4 Fuses
The battery pack is equipped with a 30 A fuse protected by a cover .
F
You may not mend or by-pass a defect fuse. Always replace it with an
identical one of the same amperage.
F
AAT Alber Antriebstechnik GmbH could offer you replacements of
the fuses!
F
Before you exchange the fuses, please remove the charger from the
battery pack!
To exchange the fuse, pull out the cover and the fuse ; insert the new
one and replace the cover.
F
Should your fuses burn out frequently, please contact AAT Alber
Antriebstechnik GmbH or your authorized dealer.
38
s-max sella · 160 kg
4
3
charger LED orange batteries are being charged
charger LED green batteries are charged, retaining of the charge
voltage converter beeping 12 V supply is low