With an FSO module
1 2 3 4
Customer motor PTC sensor(s)1
Thermistor relay(s)2
K74
(K75)
(K76)
FSO module
FSE module (optional)
1)
3
Drive STO4
1)
The FSE module is included in the calculations only if:
a safety encoder is used in the application, and
the FSO-21 module is configured to activate the SS1 function (stop category 1) in overtemperature situations, and
the ramp monitoring method is used in the SS1 function.
PFD
avg
(1…3 relays)T
1
HFTSIL
5.02E-22 years01
3AXD10000331763 E
28 ATEX-certified motor thermal protection function with PTC thermistor relays (+L513+Q971)