EasyManua.ls Logo

ABB 3AXD50000035158 - With an FSO Module

ABB 3AXD50000035158
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
With an FSO module
1 2 3 4 5
Customer motor Pt100 sensor(s)1
Pt100 relay(s)2
K71.1…3
(K72.1…2)
(K73.1…3)
Extension relay(s)3
A81
(A82)
(A83)
FSO module
FSE module (optional)
1)
4
Drive STO5
1)
The FSE module is included in the calculations only if
a safety encoder is used in the application, and
the FSO-21 module is configured to activate the SS1 function (stop category 1) in overtemperature situations, and
the ramp monitoring method is used in the SS1 function.
PFD
avg
(3, 5, or 8 relays)T
1
HFTSIL
1.16E-32 years01
3AXD10000331763 E
40 ATEX-certified motor thermal protection function with Pt100 relays (+L514+Q971)

Table of Contents

Related product manuals