Hardware description 11
Example: upright position, frames R4 to R9
Degree of protection
This table shows the degree of protection of the flange-mounted drive. In frames R1,
R2, R4 and R5 to R9 the degree of protection of IP55 (UL Type 12) for the front is not
possible because the cover cannot be installed.
Frame size Plus code Degree of
protection
Degree of protection with flange
Front Back
R1 - IP21 (UL Type 1) IP20 (UL Open Type) IP55 (UL Type 12)
R1 B056 IP55 (UL Type 12) IP20 (UL Open Type) IP55 (UL Type 12)
R2 - IP21 (UL Type 1) IP20 (UL Open Type) IP55 (UL Type 12)
R2 B056 IP55 (UL Type 12) IP20 (UL Open Type) IP55 (UL Type 12)
R3 - IP21 (UL Type 1) IP20 (UL Open Type) IP55 (UL Type 12)
R3 B056 IP55 (UL Type 12) IP55 (UL Type 12) IP55 (UL Type 12)
R4 - IP21 (UL Type 1) IP20 (UL Open Type) IP55 (UL Type 12)
R4 B056 IP55 (UL Type 12) IP20 (UL Open Type) IP55 (UL Type 12)
R5 - IP21 (UL Type 1) IP20 (UL Open Type) IP55 (UL Type 12)
R6 - IP21 (UL Type 1) IP20 (UL Open Type) IP55 (UL Type 12)
R7 - IP21 (UL Type 1) IP20 (UL Open Type) IP55 (UL Type 12)
1 Hood (in the cooling air
channel; required for UL
Type 12)
2 Top flange bracket
3 Mounting plate
4 Lifting hole
5 Drive heat sink in the cooling
air channel
6 Side flange bracket
7 Drive front side
8 Bottom flange bracket
1
4
7
5
2 3
6
4
8
4
4