8 ACS 300 User’s Manual
Chapter 1 - Overview of This Manual
Table 1-2 ACS 300 frequency converter types for 50 Hz and
60 Hz supplies. Mains supply 380 to 480 V.
1)
Allowed for one minute every ten minutes at 50 °C ambient.
2)
The impedance of mains supply affects the input current.
3)
The single underline (_) in the type designation stands for “0” or
“1”.
Type
designation
3)
Frame
Rated
input
current
2)
3-phase
I
1
[A]
Output current
Maximum
permissible rated
motor power
P
N
[kW]
Weight
[kg]
Rated
current
I
N
[A]
Short-term
overload
current
I
OVER
[A]
1)
ACS 3_1-1P6-3 R1 3.0 2.5 3.8 0.75 4.6
ACS 3_1-2P1-3 R1 3.9 3.2 4.8 1.1 4.6
ACS 3_1-2P7-3 R1 5.0 4.1 6.2 1.5 4.6
ACS 3_1-4P1-3 R1 7.5 6.2 9.3 2.2 4.6
ACS 3_1-4P9-3 R1 9.1 7.5 11.0 3.0 4.6
ACS 3_1-6P6-3 R1 12.1 10.0 15.0 4.0 4.6
ACS 3_1-8P7-3 R2 10.6 13.2 19.8 5.5 13.0
ACS 3_1-012-3 R2 14.4 18.0 27.0 7.5 13.0
ACS 3_1-016-3 R2 21.0 24.0 27.0 11.0 13.0