48 ACS 300 User’s Manual
Chapter 7 - Drive Parameters
111 DEC 2 0.1 – 1800 s 3 s 52 Time for Ref Max f - Ref Min f
deceleration ramp
112 FAULT MEMORY Display only - 53 The last three fault indications
113 NOM RPM (0) 0 – 19999 1500 53 Nominal motor speed
114 NOM FREQ (0) 50 – 400 Hz 50 Hz 53 Nominal motor frequency
115 NOM VOLT (0) 200 – 240V or
360 - 500 V
2)
220V or
480 V
2)
54 Nominal motor voltage
116 COS PHI (0) 0.40 – 0.99 0.75 54 Motor power factor
117 SUPPLY VOLT
2)
(0) 380 to 480 V 480 V 54 Supply voltage selection
118 LANGUAGE GB,SF,S,D,I,F,
E,NL,DK
English 54 Display language selection
119 TEMP MOD Display only - 54 Calculated motor temperature
120 HOURS Display only - 54 Operation timer
1)
Depends on the selected nominal motor frequency (Page 1 parameter NOM FREQ)
2)
Only 400 V series
Note! Maximum value for ACC/DEC time is going to be lower
than 1800 s , when the absolute value of MIN FREQ –
MAX FREQ is <100 Hz.