236 ACS550 User’s Manual
Technical Data
Air Flow, 380…480 Volt Drives
The following table lists heat loss and air flow data for 380…480 Volt drives.
-07A5-2 R1 81 276 44 26
-012A-2 R1 116
404 44 26
-017A-2 R1 161
551 44 26
-024A-2 R2 227
776 88 52
-031A-2 R2 285 373 88 52
-046A-2 R3 420
1434 134 79
-059A-2 R3 536 1829 134 79
-075A-2 R4 671 2290 280 165
-088A-2 R4 786
2685 280 165
-114A-2 R4 1014 3463 280 165
-143A-2 R6 1268 4431 405 238
-178A-2 R6 1575
5379 405 238
-221A-2 R6 1952 6666 405 238
-248A-2 R6 2189 7474 405 238
Drive Heat Loss Air Flow
ACS550-x1- Frame Size W
BTU/Hr m
3
/h ft
3
/min
-03A3-4 R1 40
137 44 26
-04A1-4 R1 52 177 44 26
-05A4-4 R1 73 249 44 26
-06A9-4 R1 97
331 44 26
-08A8-4 R1 127 433 44 26
-012A-4 R1 172 587 44 26
-015A-4 R2 232
792 88 52
-023A-4 R2 337
1150 88 52
-031A-4 R3 457 1560 134 79
-038A-4 R3 562
1918 134 79
-044A-4 R4 667 2276 280 165
-059A-4 R4 907
3096 280 165
-072A-4 R4 1120
3820 280 165
-077A-4 R5 1295 4420 168 99
-096A-4 R5 1440
4915 168 99
-124A-4 R6 1940
6621 405 238
-157A-4 R6 2310
7884 405 238
-180A-4 R6 2810 9590 405 238
-195A-4 R6 3050
10416 405 238
Drive Heat Loss Air Flow
ACS550-x1- Frame Size W
BTU/Hr m
3
/h ft
3
/min