Technical data 17
Environmental limits
Disclaimers
Generic disclaimer
The manufacturer shall have no obligation hereunder with respect to any product
which (i) has been improperly repaired or altered; (ii) has been subjected to misuse,
negligence or accident; (iii) has been used in a manner contrary to the Manufacturer's
instructions; or (iv) has failed as a result of ordinary wear and tear.
Cyber security disclaimer
This product is designed to be connected to and to communicate information and
data via a network interface. It is Customer's sole responsibility to provide and
continuously ensure a secure connection between the product and Customer network
or any other network (as the case may be). Customer shall establish and maintain
any appropriate measures (such as but not limited to the installation of firewalls,
application of authentication measures, encryption of data, installation of anti-virus
programs, etc) to protect the product, the network, its system and the interface
against any kind of security breaches, unauthorized access, interference, intrusion,
leakage, and/or theft of data or information. ABB and its affiliates are not liable for
damages and/or losses related to such security breaches, any unauthorized access,
interference, intrusion, leakage and/or theft of data or information.
Operation Storage Transportation
Installation site altitude max 4000 m (13123 ft) - -
Air temperature -20 °C to +55 °C
(-4 °F to 131 °F)
-40 °C to +70 °C
(-40 °F to 158°F)
-40 °C to +70 °C
(-40 °F to 158 °F)
Relative humidity 95% (non-condensing)
Contamination levels
(IEC 60721-3-3, IEC
60721-3-2, IEC 60721-1-3-1)
3C3
Sinusoidal vibration 61800-5-1 ed 2.
EN 60082-2-6 test
Fc (1g)
class 2M3 in acc.
with EN 60082-2-6
Shock class 3M4 in acc. with
EN 60062-2-27
class 2M2 in acc.
with EN 60082-2-27
Free fall IEC-60068-2-31,
drop height 1 m.
(3.3 ft.)
EMC compliance EN 61800-3:2004 + A1:2012