29.18 DC voltage ramp down speed real32 0…30000 V/s 1 = 1 V/s
29.19 DC voltage ramp up speed real32 0…30000 V/s 1 = 1 V/s
29.20 DC voltage proportional gain real32 0.00 … 1000.00 - 100 = 1
29.21 DC voltage integration time real32 0.0000 … 60.0000 s 10000 = 1 s
29.25 DC capacitance source uint16 0…1 - 1 = 1
29.26 Used DC capacitance real32 0.000 … 1000.000 mF 1000 = 1 mF
29.70 Speed data point 1 real32 0.00 … 30000.00 rpm 100 = 1 rpm
29.71 Torque data point 1 real32 0.0 … 1600.0 % 10 = 1%
29.72 Speed data point 2 real32 0.00 … 30000.00 rpm 100 = 1 rpm
29.73 Torque data point 2 real32 0.0 … 1600.0 % 10 = 1%
29.74 Speed data point 3 real32 0.00 … 30000.00 rpm 100 = 1 rpm
29.75 Torque data point 3 real32 0.0 … 1600.0 % 10 = 1%
29.76 Speed data point 4 real32 0.00 … 30000.00 rpm 100 = 1 rpm
29.77 Torque data point 4 real32 0.0 … 1600.0 % 10 = 1%
29.78 Speed data point 5 real32 0.00 … 30000.00 rpm 100 = 1 rpm
29.79 Torque data point 5 real32 0.0 … 1600.0 % 10 = 1%
30 Limits
30.01 Limit word 1 uint16 0000h…FFFFh - 1 = 1
30.02 Torque limit status uint16 0000h…FFFFh - 1 = 1
30.11 Minimum speed real32 -30000.00 … 30000.00 rpm 100 = 1 rpm
30.12 Maximum speed real32 -30000.00 … 30000.00 rpm 100 = 1 rpm
30.13 Minimum frequency real32 -500.00 … 500.00 Hz 100 = 1 Hz
30.14 Maximum frequency real32 -500.00 … 500.00 Hz 100 = 1 Hz
30.15 Maximum start current enable uint16 0…1 - 1 = 1
30.16 Maximum start current real32 0.00 … 30000.00 A 100 = 1 A
30.17 Maximum current real32 0.00 … 30000.00 A 100 = 1 A
30.18 Minimum torque sel uint32 --1 = 1
30.19 Minimum torque 1 real32 -1600.0 … 0.0 % 10 = 1%
30.20 Maximum torque 1 real32 0.0 … 1600.0 % 10 = 1%
30.21 Minimum torque 2 source uint32 --1 = 1
30.22 Maximum torque 2 source uint32 --1 = 1
30.23 Minimum torque 2 real32 -1600.0 … 0.0 % 10 = 1%
30.24 Maximum torque 2 real32 0.0 … 1600.0 % 10 = 1%
30.25 Maximum torque sel uint32 --1 = 1
30.26 Power motoring limit real32 0.00 … 600.00 % 100 = 1%
30.27 Power generating limit real32 -600.00 … 0.00 % 100 = 1%
30.30 Overvoltage control uint16 0…1 - 1 = 1
30.31 Undervoltage control uint16 0…1 - 1 = 1
30.35 Thermal current limitation uint16 0…1 - 1 = 1
(Parameters 30.10130.149 only visible when IGBT supply unit control activated by 95.20)
30.101 LSU limit word 1 uint16 0000h…FFFFh - 1 = 1