Parameters 377
Warning The drive generates a warning (AF80 INU-LSU comm loss). 1
Fault Drive trips on 7580 INU-LSU comm loss.2
61
61 D2D and DDCS
transmit data
Defines the data sent to the DDCS link.
See also parameter group 60 DDCS communication.
61.01 M/F data 1
selection
Preselects the data to be sent as word 1 onto the
master/follower link.
See also parameter 61.25 M/F data 1 value, and section
Master/follower functionality (page 31).
Follower CW
None None. 0
CW 16bit Control Word (16 bits) 1
SW 16bit Status Word (16 bits) 4
Act1 16bit Actual value ACT1 (16 bits)
Note: Using this setting to send a reference to the follower is
not recommended as the source signal is filtered. Use the
“reference” selections instead.
5
Act2 16bit Actual value ACT2 (16 bits)
Note: Using this setting to send a reference to the follower is
not recommended as the source signal is filtered. Use the
“reference” selections instead.
6
Follower CW A word consisting of bits 0…11 of 06.01 Main control word
and the bits selected by parameters 06.45…06.48.
Note: Bit 3 of the follower control word is kept on as long as
the master is modulating, and when it switches to 0, the
follower coasts to a stop.
27
Used speed
reference
24.01 Used speed reference (page 226). 6145
Torque reference
act 5
26.75 Torque reference act 5 (page 249). 6731
Torque reference
used
26.02 Torque reference used (page 242). 6658
ACS800 System
ctrl SW
A follower status word compatible with an ACS800 (System
Control Program) master. With this setting, status word bit 0 is
cleared whenever the run enable signal is missing.
28
Follower CW B6
high
Otherwise identical to selection Follower CW, but bit 6 of the
follower control word is also kept on as long as the master is
modulating. This will allow the follower to stop along the stop
ramp of the master.
29
Other Source selection (see Terms and abbreviations on page 114). -
61.02 M/F data 2
selection
Preselects the data to be sent as word 2 onto the
master/follower link.
See also parameter 61.26 M/F data 2 value.
For the selections, see parameter 61.01 M/F data 1 selection.
Used speed
reference
61.03 M/F data 3
selection
Preselects the data to be sent as word 3 onto the
master/follower link.
See also parameter 61.27 M/F data 3 value.
For the selections, see parameter 61.01 M/F data 1 selection.
Torque
reference act
5
No. Name/Value Description Def/FbEq16