DescriptionExample valueNameIndex
I/O settings
Sets the diagnostic pulse of digital input
X113:4 on or off.
OnDI X113:4 diag pulse
on/ off
SAFEIO.36
On: The input monitors that it receives test
pulses.
Sets the diagnostic pulse of digital input
X114:4 on or off.
OnDI X114:4 diag pulse
on/ off
SAFEIO.40
On: The input monitors that it receives test
pulses.
Sets the diagnostic pulse of digital output
X114:8 on or off.
OnDO X114:8 diag
pulse on/off
SAFEIO.57
On: The output monitors that it receives test
pulses.
Sets the logic state of digital output X114:8.Active highDO X114:8 logic
state
SAFEIO.75
Active high: The digital output is on when
the indicated signal is active.
For option +Q965, ABB has configured the
SLS indication signal to this digital output at
the factory. Make sure that this value corres-
ponds to the actual wiring. See the circuit
diagrams of the delivery.
Parameters for the SMS function
These parameters are related to the SMS function (version 1) of the FSO module.
DescriptionExample valueNameIndex
Activates or deactivates the SMS function
and shows the version of the SMS function.
Version 1SMS activity and ver-
sion
200.71
Disabled: Deactivates the SMS function
(default).
Version 1: Activates version 1 of the SMS
function.
Version 2: Activates version 2 of the SMS
function (for more information, see the FSO
module user’s manual).
For option +Q965, ABB has configured the
SMS function (Version 1) at the factory.
Adjust the value if necessary.
Sets the negative speed limit that trips the
drive for the SMS function.
-2000 rpmSMS trip limit negat-
ive
SMS.13
Note: You cannot set this limit above the
general zero speed limit (parameter FSO-
GEN.52).
Sets the positive speed limit that trips the
drive for the SMS function.
2000 rpmSMS trip limit positiveSMS.14
Note: You cannot set this limit below the
general zero speed limit (parameter FSO-
GEN.52).
Parameters for the SSM function
There are four separate SSM functions (SSM1...4) in the FSO module. The SSM functions
are identical and the configuration is done similarly, only the parameter numbers differ. The
46 Parameter settings