EQUIPMENT SPECIFICATION
2019-04-30 15
AFS670 | PRECAUTIONS AND SAFETY
4 Equipment Specification
4.1 Ambient Conditions
The equipment must be stored, transported and operated according to the ambient con-
ditions specified below.
4.2 EMC/ESD and Safety
Table 1: Climatic conditions during operation
Parameter Specification
- Ambient air temperature Standard
up to 2000 m ASL 0 °C ... +60 °C
(up to 6562 ft ASL +32 °F ... +140 °F)
above 2000 m ASL 0 °C ... +50 °C
(above 6562 ft ASL +32 °F ... +122 °F)
Extended
up to 2000 m ASL -40 °C ... +70 °C
(up to 6562 ft ASL -40 °F ... +158 °F)
above 2000 m ASL -40 °C ... +60 °C
(above 6562 ft ASL -40 °F ... +140 °F)
Extended with Conformal Coating
up to 2000 m ASL -40 °C ... +70 °C
(up to 6562 ft ASL -40 °F ... +158 °F)
above 2000 m ASL -40 °C ... +60 ° C
(above 6562 ft ASL -40 °F ... +140 °F)
Humidity 5 % ... 95 % (non-condensing)
Air pressure min. 600 hPa (+13123 ft; +4000 m)
max. 1060 hPa (-1312 ft; -400 m)
Table 2: Climatic conditions during storage
Parameter Specification
- Ambient air temperature -40 °C ... +85 °C
(-40 °F ... +185 °F)
Humidity 5 % ... 95 % (non-condensing)
- Air pressure min. 600 hPa (+4000 m; +13123 ft)
max. 1060 hPa (-400 m; -1312 ft)
Table 3: EMC
Parameter Specification
Radiated emission EN 55032 Class A
FCC 47 CFR Part 15 Class A
EN 61000-6-4 Fulfilled
Conducted emission EN 55032 DC supply connection Class A
FCC 47 CFR Part 15 DC supply connection Class A
EN 61000-6-4 DC supply connection Fulfilled
EN 55032 Telecommunication connections Class A
EN 61000-6-4 Telecommunication connections Fulfilled