Technical data
87
3ADW000462R0301 DCS880 Hardware Manual e c
Technical data
Auxiliary incoming power XAUX (X99)
Input circuit XAUX (X99)
Features a hardware filter
and a voltage limitation
.
Armature circuit interface
The function for the armature circuit interface consist of:
Firing the armature bridge of 6 or 12 thyristors.
High ohmic measurement of DC and AC voltages.
Residual measurement current of armature circuit to ground
= 5 mA at 500 V supply (
1 M).
Interface for the current transformers for current measurement.
Snubber circuit for the thyristor protection together with R1 on the heatsink.
Interface for heatsink temperature measurement with a PTC.
Fuses for overvoltage protection and field circuit.
Auxiliary voltage 115 V
AC
230 V
AC
230 V
DC
Tolerance -15 % / +10 % -15 % / +10 % -15 % / +10 %
Frequency 45 Hz ... 65 Hz 45 Hz ... 65 Hz -
Power consumption 120 VA 120 VA -
Power loss 60 W 60 W 60 W
Inrush current 20 A / 20 ms 10 A / 20 ms 10 A / 20 ms
Recommended fusing 6 AT 6 AT 6 AT
Mains buffering min. 30 ms min. 300 ms min. 150 ms
Powerfail < 95 V
AC
< 95 V
AC
< 140 V
DC
SF_PINF_001_in-output_b.ai
3.15 AT
R300
NTC
-
U
R310
F302
XAUX (X99):