Technical data
90
3ADW000462R0301 DCS880 Hardware Manual e c
Layout
SDCS-BAB-F01 for module sizes H1 and H2:
Layout SDCS-BAB-F02 for module sizes H3 and H4:
Location
The SDCS-BAB-F0x is located between the power part and the control board SDCS-CON-H01.
Functions
The SDCS-BAB-F0x is a three-phase half-controlled field exciter. The field exciter is directly supplied
from the armature mains. Its firing pulses and snubbers are located on the
SDCS-PIN-H01. For connection details see next pages.
Number of threads through the hole in the T100 (e.g. 3 threads equal 2 loops)
Size Converter type Used type Used fuses T100 threads I
F
[A]
H1 DCS880-S01-0020 ...
DCS880-S02-0025
SDCS-BAB-F01 F100 ... F102 on SDCS-PIN-H01
KTK 25 = 25 A
4 0.3 ... 6
H1 DCS880-S01-0045 ...
DCS880-S02-0100
SDCS-BAB-F01 F100 ... F102 on SDCS-PIN-H01
KTK 25 = 25 A
3 1 ... 12
H2 DCS880-S01-0135 ...
DCS880-S02-0300
SDCS-BAB-F01 F100 ... F102 on SDCS-PIN-H01
KTK 25 = 25 A
2 1 ... 18
H3 DCS880-S01-0315 ...
DCS880-S02-0520
SDCS-BAB-F02 F100 ... F102 on SDCS-PIN-H01
KTK 25 = 25 A
1 2 ... 25
H4 DCS880-S01-0610 ...
DCS880-S02-1000
SDCS-BAB-F02 F401 ... F403 in drive
KTK 30 = 30 A
1 2 ... 30
X6
X10
X15
X5
X3 X2 X1
X4
21
1
F+ F-
T100
SF_BABF_001_a.ai
SF_BABF_001_a.ai
X6
X10
X15
X5
X3 X2 X1
X4
21
1
T100
X10 : F-
X10 : F+