EasyManua.ls Logo

ABB DCS880 - Fault Functions and Supervision; Motor Thermal Protection and Fieldbus; Communication and Motor Data

ABB DCS880
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Parameters
3ADW000480R0101 DCS880 Quick guide e a
31 Fault functions and fault levels
Configuration of external events. Selection of the drive behavior in fault
situations.
32 Supervision
Configuration of signal supervision functions 1 … 3. Three values can be
monitored. A warning or fault is generated whenever predefined limits are
exceeded.
33 Generic timer & counter
Configuration of maintenance timers/counters.
35 Motor thermal protection
Motor thermal protection settings such as temperature measurement
configuration and load curve definition.
36 Load analyzer
Peak value and amplitude logger settings.
37 User load curve
Settings for user load curve.
40 Process PID
Parameter values for process PID controller.
42 Shared motion (2nd motor)
Configuration of 2
nd
motor.
44 Mechanical brake control
Configuration of mechanical brake.
45 Energy efficiency
Settings for the energy saving calculators.
46 Monitoring/Scaling settings
Speed supervision settings, signal filtering and general scaling settings.
47 Data storage
Data storage parameters that can be written to and read from using other
parameters’ source and target settings.
49 Panel port communication
Communication settings for the control panel port on the drive.
50 Fieldbus adapter (FBA)l
Fieldbus communication configuration.
51 FBA A settings
Fieldbus adapter A configuration.
52 FBA A data in
Selection of data sent by fieldbus adapter A to the master (e.g. PLC).
53 FBA A data out
Selection of data sent by the master (e.g. PLC) to fieldbus adapter A.
54 FBA B settings
Description see group 51 FBA A settings.
55 FBA B data in
Description see group 52 FBA A data in.
56 FBA B data out
Description see group 53 FBA A data out.
58 Embedded fieldbus
Embedded fieldbus (EFB) configuration.
60 DDCS Communication
DDCS communication configuration.
61 D2D and DDCS transmit data
Defines the data sent from the drive to the DDCS/D2D link.
62 D2D and DDCS receive data
Defines the data sent from the DDCS/D2D link to the drive.
70 DCSLink Communication
Defines the DCSLink communication.
74 … 89 Application specific
groups
Groups used for application programming.
90 Feedback selection
Motor and load feedback configuration.
91 Encoder module settings
Configuration of the encoder interface modules.
92 Encoder 1 configuration
Settings for encoder 1.
93 Encoder 2 configuration
Settings for encoder 2.
94 OnBoard speed feedback
configuration
Settings for analog tacho and OnBoard encoder.
95 HW configuration
Various hardware-related settings.
96 System
Language selection; access levels; macro selection; parameter save and
restore; control board reboot; user parameter sets; unit selection; data
logger triggering; parameter checksum calculation; user lock.
99 Motor data
Motor configuration settings.

Other manuals for ABB DCS880