Mounting procedure
Fasten each sensor with two M4-screws. Safety screw SM4x20 (2TLA020053R4200) is
recommended. The DA 2B mounting spacers must be used in order to physically protect Eden from
damage.
1. Use max tightening torque 1.0 Nm on screws.
2. Lock screw with Loctite or similar if necessary, to prevent easy dismounting (refer to risk
assessment).
3. Tighten the M12-contact with tightening torque 0.6 Nm. A torque wrench is recommended
to ensure a tight connection and IP69K.
DA 2B
Mounting spacer (DA 2B)
Torque wrench for M12-connector