7 LED indication
The non-safe status LED on Adam shows the status of the Eden sensor and the output status as
follows:
LED on Adam
Description
Safety circuit
Green
Valid Eva within range
Closed
Flashing green
Valid Eva within range, waiting for reset
Open
Flashing red/green
Valid Eva within range, no valid in signal
Open
Red
Valid Eva out of range
Open
Fast flashing green
Valid Eva is within 2 mm from maximum detection
distance
Closed
Fast flashing red
Fail safe mode
Open
Flashing red
No Eva programmed
Open
When Adam DYN-Status operates in StatusBus mode, the following LED statuses are also possible:
LED on Adam StatusBus
Description
Double flash, red
0.11/0.2/0.11/0.67 s,
on/off/on/off
Sensor in StatusBus mode, off.
“Ready slave” Address 0.
Eva is not within detection
distance during
addressing.
Double flash, green
0.11/0.2/0.11/0.67 s,
on/off/on/off
Sensor in StatusBus mode, on.
Address 0.
Addressed from 130 to 0.
Eva within detection
distance.
Off for 5 s, then flickering flash
0.07/1.9 s, on/off
Sensor in StatusBus mode, on.
Teach mode.
The flashing usually lasts for
1-4
seconds during the
addressing
(teach) process.
Burst with stress flash. Burst
cycle: 0.8/0.4 s, on/off
At the command from Pluto
Manager.