2TLC172271M0201 Rev D 30
11 Technical data
ABB Electrification Sweden AB, Jokab Safety
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
+24 VDC +15 % -40 %
Use SELV/PELV
30 mA at 24 VDC
35 mA at 18 VDC
(45 mA at 12 VDC)
Reset indication lamp output
30 mA max on pin 5 (Adam DYN-Reset)
15 mA max on pin 5 (Adam DYN-Info)
Voltage drop (DYNlink out)
OFF-state current (DYNlink out)
Storage: -40…+70°C
Operation: -40…+70°C
35 to 85 % (with no icing or condensation)
Response time at activation
Response time at deactivation
Useful lifetime / mission time
Housing: Polybutylene terephthalate (PBT)
Molding: Epoxy
M12 5-pole male
Torque: 0.6 Nm
Assured release distance (S
ar
)
Assured operating distance (S
ao
)
Rated operating distance (S
n
)