2TLC172271M0201 Rev D 7
3 Models of Adam and Eva
Eden communicates with a dynamic signal generated by the control device, a Vital, a Pluto Safety
PLC or a URAX. Up to 30 Eden sensors can be connected in series to Vital 1. Ten Eden sensors can
be connected to one Pluto or URAX input, without reducing the achieved performance level.
It is also possible to connect safety light beams, Tina adaptor units and E-stops in the same safety
circuit. Adam and Eva are acquired separately, and it is possible to mix different models of Adam
DYN in the same safety circuit.
Adam DYN
Adam DYN exists in three different models: Adam DYN-Info, Adam DYN-Reset and Adam DYN-
Status.
Adam DYN-Info M12-5
Dynamic model with information output.
Adam DYN-Reset M12-5
Dynamic model with built in monitored reset and indication
lamp output.
Adam DYN-Status M12-5
Dynamic model with StatusBus function. Adam DYN-Status
is delivered configured for static information output, but
switches to StatusBus configuration when a StatusBus
master has been detected. Requires a Pluto as master. (For
more information about the Pluto, refer to the user manual
at www.abb.com/jokabsafety)
Eva
Eva exists in two different models: Eva General code and Eva Unique code. It is possible to mix
different models of Eva in the same safety circuit.
Eva General code
The Eva units with general code have all the same code and
fulfills the requirement for a low-level coded interlocking
device according to EN ISO 14119:2013. It is possible to mix
different models of Eva in the same safety circuit.
Eva Unique code
The Eva units with unique code have all a different unique
code. The unique models fulfill the requirements for a high-
level coded interlocking device according to EN ISO
14119:2013.