5 Electrical connections
5.7.4 AD Combi I/O, DSQC 327 (optional)
3HAC 16245-1 A 119
Connections,
connector X2
If supervision of the supply voltage is required, a bridge connection can be made to an
optional digital input. The supervision instruction must be written in the RAPID program.
This is described in the User’s Guide.
The table below show the connections to connector X2:
Connections,
connector X3
The table below show the connections to connector X3:
Unit function Signal name X1 pin
Optically isolated output Out ch 1 1
Optically isolated output Out ch 2 2
Optically isolated output Out ch 3 3
Optically isolated output Out ch 4 4
Optically isolated output Out ch 5 5
Optically isolated output Out ch 6 6
Optically isolated output Out ch 7 7
Optically isolated output Out ch 8 8
Optically isolated output 0 V for outputs 1-8 9
Optically isolated output 24 V for outputs 1-8 10
Unit function Signal name X2 pin
Optically isolated output Out ch 9 1
Optically isolated output Out ch 10 2
Optically isolated output Out ch 11 3
Optically isolated output Out ch 12 4
Optically isolated output Out ch 13 5
Optically isolated output Out ch 14 6
Optically isolated output Out ch 15 7
Optically isolated output Out ch 16 8
Optically isolated output 0 V for outputs 9-16 9
Optically isolated output 24 V for outputs 9-16 10
Unit function Signal name X3 pin
Optically isolated input In ch 1 1
Optically isolated input In ch 2 2
Optically isolated input In ch 3 3
Optically isolated input In ch 4 4
Optically isolated input In ch 5 5
Optically isolated input In ch 6 6
Optically isolated input In ch 7 7
Optically isolated input In ch 8 8
Optically isolated input 0 V for inputs 1-8 9
Optically isolated input Not used 10