5 Electrical connections
5.7.5 Analog I/O, DSQC 355 (optional)
3HAC 16245-1 A 121
5.7.5 Analog I/O, DSQC 355 (optional)
General The analog I/O unit handles communication between the robot system and any external sys-
tems through analog sensors.
Technical data
Also see Product Specification for controller S4Cplus.
Further informa-
tion
For setup parameters, see User’s Guide - System Parameters, Topic: Controller. Also see the
Circuit Diagram.
Layout, DSQC
355
The figure below show the layout of the DSQC 355 board:
xx0100000238
No. of analog inputs 4 (-10 V/+10 V)
No. of analog outputs 3 (-10 V/+10 V)
1 (4-20 mA))
No. of analog outputs 2 (galvanically isolated from the controller electronics)
Supply voltage 24 VDC
X3 Not used
X5 DeviceNet input and ID connector
X7 Analog outputs
X8 Analog inputs
DSQC 355
ABB Flexible Automation
Bus status
Analog I/O
X8
X8
S3
S2
X3
X3
X5
X5
X2
X7
X7