121
Note that all version checks are performed by REF542CONF before configuration
download. Therefore, the fault can occur only after a REF 542plus firmware
upgrade/downgrade or after FLASH configuration data corruption.
The following table describes signalling/handling of the configuration faults:
Faults/Errors Signalling
Level
No configuration HMI error message "Waiting new config."
1
Incompatible Version HMI error message "Software changed"
1
COM configuration file
format
HMI error message "WRONG COM CONFIG."
SPA event 102E60
3
COM TCP-IP incompatible
version
HMI error message "WRONG TCP-IP CONFIG."
SPA event 102E61
3
COM MOD-TCP
incompatible version
HMI error message "WRONG MODTCP CONFIG."
SPA event 102E62
3
COM WEBREF
incompatible version
HMI error message "WRONG WEBREF CONFIG."
SPA event 102E63
3
COM SMS incompatible
version
HMI error message "WRONG SMS CONFIG."
SPA event 102E61
3
COM module incompatible
version
HMI error message "WRONG COMMODULE
CONF."
SPA event 102E61
3
Functions checking HMI error message "WRONG CONFIGURATION"
SPA event 0E43
1
Hardware checking Protection functions: See 2.4
DSP AI20mA functions: See 2.6 AI20mA
DSP (Digital Signal Processor)
The DSP supervision verifies correct DSP start-up and correct DSP working status
during normal operation.
The DSP start-up supervision verifies:
*
DSP version
It is used to verify communication at start-up and to check SW version
compatibility.
*
DSP Analogue Inputs calibration factors
The data is retrieved from the Analogue Input module. If the data is not present
or if it is corrupted, the system will be stopped because it is not able to guarantee
reliable measurements and safe protection executions.
*
DSP configuration
The DSP configuration is built by the MC from the Analogue Input and
Protections configuration. It is sent to the DSP that performs a consistency check
on it.