DP-V0 communication
58
Example 4: Writing a PROFIdrive parameter (word)
In this example, current parameter settings are saved to the
FLASH memory of the drive. This is done by setting the value of
PROFIBUS Parameter No. 971 (3CBh) to 1.
Note that the drive always observes the Control Word (CW)
and Reference (REF) bytes. The values shown below are
examples.
Write:
Request 23CB000000000001047F3415
Response 13 CB 00 00 00 00 00 00 03 37 34 15
Param. Value
CW REFIND
Parameter Number (971 Dec)
Request (Parameter value write)
Response (Parameter value updated)
Parameter Number (971 Dec)
IND Param. Value SW ACT