Quick start-up guide
21
Set the PPO type, baud rate and node number.
Mechanical and electrical installation
Set the node address using the rotary switches on the module.
(If the node address is set by software, set the switches to the
“0” position.)
Set the bus termination switch to the desired position.
Insert the RPBA-01 into its specified slot in the drive (SLOT2 for
ACS550, SLOT1 for ACS800).
Fasten the two screws.
Plug the fieldbus connector to the module.
Drive configuration
Power up the drive.
The detailed procedure of activating the drive for
communication with the module is dependent on the drive type.
Normally, a parameter must be adjusted to activate the
communication. Refer to the Firmware Manual of the drive for