ABB | SACE Emax 2
4 | © 2019 ABB | 1SDH001000R0002 - ECN000109166 - Rev. D Emax E2.2-E4.2-E6.2 circuit-breakers | 1 - Contents
Emax E2.2-E4.2-E6.2 circuit-breakers
1 - Contents
Overview
This manual contains instructions on the operations to be performed on Emax E2.2-E4.2-E6.2 circuit-breakers
throughout their life cycle, from reception to installation, and from commissioning to subsequent maintenance
during operation, with particular attention to the environment at the end of the life cycle of the product.
Reception Installation Commissioning Maintenance Disposal
Figure 1
Integrated informations
A full description of Emax 2 circuit-breakers is available in document 1SDH001330R1002 (Emax 2 engineering
manual) available on the website ABB library.
IMPORTANT: all codes and documents mentioned in this document refer to Emax 2
configured with Trip unit Firmware version= 3.xx.
If the Firmware version of the Trip unit on the Emax 2 circuit-breaker =2.xx, consult
document 1SDH001330R0002 available on the website ABB library.
recipients
This manual refers to two user profiles, as defined by standard IEC 60050:
Electrically Skilled Person (IEV 195-04-01): person with relevant education and experience to enable him
or her to perceive risks and to avoid hazards which electricity can create.
Trained Persons in the electrical field (IEV 195-04-02): person adequately advised or supervised by electrically
skilled persons to enable him or her to perceive risks and to avoid danger which electricity can create.
IMPORTANT: This manual specifically indicates what operations can be performed
by people trained in the field of electricity. All the remaining operations described in
the handbook must be performed by skilled persons, in the electrical field. ABB
declines all liability for damage to persons or property caused by failure to comply
with the instructions in this document.
Specifications and supporting
documents
To ensure that the Emax 2 circuit-breaker is installed and configured correctly, please read the information in
this manual and in the technical documentation of the product, supplied with the circuit-breaker or available
in the website
ABB liBRARy
Document Description
1SDH001330R1002
Manual for design engineers with full information about the trip units and
accessories for Emax 2
1SDH001316R1002 Manual of Ekip Touch trip units for Emax 2 circuit-breakers
1SDC200023D0906 Sace Emax 2 CBs General catalog
1SDM000091R0001 Sace Emax 2 CBs Circuit diagrams
1SDH001140R0001 Communication System Interface for Emax 2 CBs
Design notes
The information in this manual was written in Italian and then translated into other languages to conform to
the laws and/or commercial requirements concerning the product.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB SACE Emax E4.2-A and is the answer not in the manual?

ABB SACE Emax E4.2-A Specifications

General IconGeneral
BrandABB
ModelSACE Emax E4.2-A
CategoryCircuit breakers
LanguageEnglish