Further measures and information for operation with a turbocharger with
cover plate on 4-stroke engines
4-stroke engine with one turbocharger
No further measures are necessary. The engine can be operated as a
naturally-aspirated engine according to the engine builder's instructions.
4-stroke engine with several turbochargers
No further measures are necessary on engines with separate air and ex-
haust gas receivers. The engine can be operated as a naturally-aspirated
engine according to the engine builder's instructions.
The air line must be closed off at the engine end because the undamaged
turbochargers build up a receiver pressure.
CAUTION
The engine can be operated according to the engine builder's instruc-
tions. Attention must always be paid to the speed of the undamaged
turbocharger. The speed limit n
Bmax
given on the rating plate must not
be exceeded.
Separate receivers
Common receiver

Table of Contents

Other manuals for ABB T566609

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB T566609 and is the answer not in the manual?

ABB T566609 Specifications

General IconGeneral
BrandABB
ModelT566609
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals