Operation Manual / TPL85-B14/-B15/-B16
Short
-term turbocharger shut-down
9
Shutting off inlets and outlets
9.3
Page 120
© Copyright 2016 ABB. All righ
ts reserved.
May 2016 HZTL2491_EN Revision B
Shutting off inlets and outlets
9.3
CAUTION
Shut off the lubricating oil supply to the turbocharger.
This applies only to engines with several turbochargers and common
air as well as exhaust gas receivers.
Shut off compressor casing outlet, gas inlet and gas outlet by fitting
cover plates.
NOTICE
In this respect, refer to the engine manufacturer's instructions.
Bypass the turbocharger
9.4
CAUTION
Shut off the lubricating oil supply to the turbocharger.
This applies to engines with one turbocharger only:
The connections are ready and pipes for the bypass are available.
Fit bypass around turbocharger.
NOTICE
In this respect, refer to the engine manufacturer's instructions.