Operation Manual / TPL85-B14/-B15/-B16
Maintenance
5
Cleaning the compressor during
operation
5.4
Page 59
© Copyright 2016 ABB. All rights reserved.
May 2016 HZTL2491_EN Revision B
Wet cleaning using external water-pressure vessel (XC3)
Operating state prerequisites for compressor cleaning with XC3
NOTICE
In order to carry out a successful cleaning procedure which has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisite must be met:
Engine load 25 to 85 %
Start the cleaning cycle according to following description
Wet clean-
ing procedure with XC3.
Compressor wet cleaning procedure with XC3
It is mandatory to fulfil the operating condition prerequisites before
cleaning compressors with XC3.
Remove the sealing plug (X).
Fill the vessel with the required volume of clean water (see the
Table
of cleaning parameters
).
5.4.1
Operating the water pres-
sure vessel