Loading...
Operation Manual / TPS44-F.. - TPS61-F..
Taking
out of operation
9
Shutting down the turbocharger
9.1
Page 115
© Copyright 2016 ABB. All rights reserved.
September 2016 HZTL2412_EN Revision F
Taking out of operation
Shutting down the turbocharger
9.1
If the turbocharger is damaged and the engine can be shut down for only
a short time for emergency repairs, proceed as follows:
Fit the cover plate.
CAUTION
Always heed precisely the engine builder's instructions in case of en-
gine operation with a blocked / throttled turbocharger!
Dismantling the turbocharger
Dismantle the turbocharger (see the section Dismantling and fitting the
turbocharger).
Do not dismantle the nozzle ring.