EasyManua.ls Logo

ABB TTF300 - Terminal Assignment (RTD;Resistors)

ABB TTF300
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ex relevant specifications
32 - EN TTF300 CI/TTF300-EN
5.4 TTF300-E5X, non-sparking + dust explosion
protection ATEX
Explosion protection
Approved for use in Zone 2 and Zone 22
Designation
II 3G Ex nA II T6
II 3 D IP 65 T 135 °C
ABB manufacturer's declaration in accordance with ATEX Directive
Temperature table
Temperature
class
Device category 3 use
T6 -50 … 56 °C (-58 ... 132,8 °F)
T5 -50 … 71 °C (-58 ... 159,8 °F)
T4 -50 … 85 °C (-58 ... 185,0 °F)
5.5 TTF300-D1X, dust explosion protection ATEX
Explosion protection
Approved for use in Zone 20
Designation
II 1D Ex tD A20 IP66 T135°C
EC type-examination test certificate BVS 06 ATEX E 029
5.6 TTF300-D2X, dust explosion protection +
intrinsic safety ATEX
Explosion protection
Approved for use in Zone 20 and Zone 0
Designation
II 1D Ex tD A20 P66 T135°C
II 1G Ex ia IIC T6
EC type-examination test certificate BVS 06 ATEX E 029
EC type-examination test certificate PTB 05 ATEX 2017 X
EC type-examination test certificate PTB 05 ATEX 2016 X
5.7 TTF300-E3X, flameproof enclosure ATEX
Explosion protection
Approved for use in Zone 1
Designation
II 2G Ex d IIC T6
EC type-examination test certificate PTB 99 ATEX 1144
5.8 TTF300-E4X, flameproof enclosure +
intrinsic safety ATEX
Explosion protection
Approved for use in Zone 1
Designation
II 2G Ex d IIC T6
II 1G Ex ia IIC T6
EC type-examination test certificate PTB 99 ATEX 1144
EC type-examination test certificate PTB 05 ATEX 2017 X
EC type-examination test certificate PTB 05 ATEX 2016 X
5.9 TTF300-L1X, intrinsically safe FM
Class I, Div. 1 + 2, Groups A, B, C, D
Class I, Zone 0, AEx ia IIC
TTF300-L1H: Control Drawing: SAP_214832
TTF300-L1P: Control Drawing: TTF300-L1..P (IS)
TTF300-L1F: Control Drawing: TTF300-L1..F (IS)
5.10 TTF300-L2X, non-incendive FM
Class I, Div. 2, Groups A, B, C, D
Class I Zone 2 Group IIC T6
TTF300-L2H:
Control Drawing: SAP_214828
Control Drawing: SAP_214830
TTF300-L2P:
Control Drawing: TTF300-L2..P (NI_PS), TTF300-L2..P (NI_AA)
TTF300-L2F:
Control Drawing: TTF300-L2..F (NI_PS), TTF300-L2..F (NI_AA)
5.11 TTF300-L3X, explosion proof FM
XP,NI, DIP Class I, II, III, Div. 1 + 2, Groups A-G, factory sealed
5.12 TTF300-L7X, explosion proof +
intrinsically safe FM
XP, NI, DIP Class I, II, III, Div. 1 + 2, Groups A-G, factory sealed
Class I, Div. 1 + 2, Groups A, B, C, D
Class I, Zone 0, AEx ia IIC T6
TTF300-L1H: Control Drawing: SAP_214832
TTF300-L1P: Control Drawing: TTF300-L1..P (IS)
TTF300-L1F: Control Drawing: TTF300-L1..F (IS)
5.13 TTF300-R1X, intrinsically safe CSA
Class I, Div. 1 + 2, Groups A, B, C, D
Class I, Zone 0, Ex ia IIC
TTF300-R1H: Control Drawing: SAP_214825
TTF300-R1P: Control Drawing: TTF300-R1..P (IS)
TTF300-R1F: Control Drawing: TTF300-R1..F (IS)
5.14 TTF300-R2X, non-incendive CSA
Class I, Div. 2, Groups A, B, C, D
TTF300-R2H:
Control Drawing: SAP_214827
Control Drawing: SAP_214895
TTF300-R2P:
Control Drawing: TTF300-R2..P (NI_PS), TTF300-R2..P (NI_AA)
TTF300-R2F:
Control Drawing: TTF300-R2..F (NI_PS), TTF300-R2..F (NI_AA)
5.15 TTF300-R3X, explosion proof CSA
XP,NI, DIP Class I, II, III, Div. 1 + 2, Groups A-G, factory sealed
5.16 TTF300-R7X, explosion proof +
intrinsically safe CSA
XP,NI, DIP Class I, II, III, Div. 1 + 2, Groups A-G, factory sealed
Class I, Div. 1 + 2, Groups A, B, C, D
Class I, Zone 0, Ex ia Group IIC T6
TTF300-R1H: Control Drawing: SAP_214825
TTF300-R1P: Control Drawing: TTF300-R1..P (IS)
TTF300-R1F: Control Drawing: TTF300-R1..F (IS)

Table of Contents

Other manuals for ABB TTF300