EasyManua.ls Logo

ABB TTF300 - Transmitter Intrinsic Safety Data; LCD Indicator Intrinsic Safety Data

ABB TTF300
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
6 - EN TTF300 CI/TTF300-EN
1.4.2 Name plate
1.4.3 Name plate: TTF300 - HART
The name plate is located on the transmitter housing.
A00265
Automation Products GmbH
Alzenau Germany 2008
TTF300
TTF300
U = + 11...30 V, I = 4...20 mA, HART
Cfg: 1 x Pt100 3W; 0...100°C
TA. = -40°C...+85°C
Sa
O-Code: TTF300-E1H
2400045678
Ser.-No: 2065342
HW. Rev. 1.06
SW. Rev. 1.01.03
PTB 05 ATEX 2017 X
II1GExia IICT6
II 2(1) G Ex [ia]ib IIC T6
II 2G (1D) Ex [iaD]ib IIC T6
T1...T4 Ta. = -40 °C ... +60 °C (Zone 0) ... +85 °C (Zone 1)
T5 Ta. =
T6 Ta. =
TTF300-E1H;
-40 °C ... +56 °C (Zone 0) ... +71 °C (Zone 1)
-40 °C ... +44 °C (Zone 0) ... +56 °C (Zone 1)
IP20
13
14
15
16
10
8
4
7
5
3
2
12
11
6
9
1
Fig. 1: Example for ATEX explosion protection
1 Project number
2 Manufacturer of transmitter
3 Country and year of manufacture
4 Order number
5 Serial number
6 Supply voltage range, typical current
range, protocol
7 Customer configuration
8 Ambient temperature range / housing
degree of protection
9 Ex mark (optional)
10Protection class of hazardous area
design (optional)
11Temperature class of hazardous area
design (optional)
12Refer to product documentation
13Software revision number / hardware
revision number
14CE mark (EC conformity)
15Type designation
16Safety integrity level (optional)

Table of Contents