Operating Instruction
IM/265D/V-EN-02
Differential Pressure Transmitte
r
265Dx, 265VS
Pos: 1 /Titelbl ätter / Copyright/BA- IA/Druck/Druckmess umformer/Titelbl att Druckmessumformer 265D, 265V @ 5\mod_1163755786968_3 101.doc @ 48426
Model 265DS, 265DC, 265DR
Model 265VS
Pos: 2 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ABB 265DS and is the answer not in the manual?

ABB 265DS Specifications

General IconGeneral
TypeDifferential Pressure Transmitter
Accuracy±0.04% of span
Process Temperature-40 to 85°C (-40 to 185°F)
Housing MaterialAluminum or Stainless Steel
Protection ClassIP66, IP67, NEMA 4X
Output Signal4-20 mA HART

Summary

Safety

General safety information

Overview of safety aspects for device operation and general safety requirements.

Intended use

Specifies measuring tasks and ranges for 265Dx and 265Vx models.

Technical limit values

Outlines device limitations for pressure, temperature, and housing protection.

Plates and symbols

Explains hazard symbols and their meanings (Danger, Warning, Caution, Attention, Important).

Name plate

Details the information presented on the device's name plate with explanations.

Compliance with Pressure Equipment Directive (97;23;EC)

Explains identification codes for devices with PS > 200 bar and PS <= 200 bar.

Qualified personnel

Specifies requirements for personnel performing installation, commissioning, and maintenance.

Safety information for inspection and maintenance

Safety warnings and procedures for opening housing, depressurizing, and maintenance.

Use in explosion-proof areas

Explosion protection type Intrinsically safe EEx I

Details safety for intrinsically safe circuits, housing opening, and Zone 0 installation.

Use in areas with combustible dust

Installation requirements and precautions for areas with combustible dust, including cable glands.

Explosion protection type Flameproof enclosure EEx d

Installation information for flameproof enclosures, including cable entries and alignment.

Aspects of Ex safety and IP protection for Australian applications

Details protection types (Ex d, Ex tD, IP 66/67) and relevant Australian standards.

Design and function

Principle of operation and construction

Explains the modular structure, measuring cell types (265Dx, 265Vx), and two-wire technology.

Mounting

General

Pre-installation checks for device design, material suitability, and relevant regulations.

IP designation

Explains IP 66/IP 67 protection types based on IEC 529 standard.

Measuring pipes

Guidelines for correct installation of measuring pipes, including length, bends, cleaning, and filling.

Electrical connection

Cable connection

Details on electrical connection via cable entry, threads, or plugs, including screw terminal suitability.

Electrical connection in the cable connection area

Describes the cable connection area, terminals, and delivery scope of glands/plugs.

Electrical connection with plug

Explains fieldbus connector types (7/8", M12x1) and pin assignments for FOUNDATION Fieldbus and PROFIBUS PA.

Communication setup

Details HART communication setup via modem, PC, or laptop, including resistance requirements.

Connecting cable

Requirements for cabling for PC/laptop communication, including wire diameter and cable length.

PROFIBUS PA differential pressure transmitter

Connection and grounding requirements for PROFIBUS PA transmitters.

Commissioning

Output signal

Describes normal operation and error detection output currents.

Write protection

How to activate and deactivate write protection to prevent unauthorized configuration changes.

Correcting the lower range value; zero shift

Procedures for correcting zero shifts caused by mounting or temperature.

Installing;Removing the button unit

Step-by-step instructions for removing and installing the button unit.

Installing;Removing the LCD display

Instructions for attaching and removing the optional LCD display.

Securing the housing cover with EEx d

Procedure for securing the housing cover with a locking screw for EEx d designs.

Operation

Operation using the buttons on the transmitter

Details the control unit, buttons for range values, and write protection switch.

Configuration

Factory settings

Default configuration parameters for HART transmitters, including range and output.

Transmitter with PROFIBUS PA communication

Factory settings for PROFIBUS PA transmitters, including measuring profile, units, and address.

Transmitter with FOUNDATION Fieldbus communication

Factory settings for FOUNDATION Fieldbus transmitters, including measuring profile and units.

Configuring the parameters without an LCD display

How to set lower range value and span using buttons directly on the transmitter.

Configuration with the LCD display

How to configure the transmitter using the LCD display and its menu items.

Parallel shift (OFFSET SHIFT)

Function to offset the characteristic to match measurement devices, setting new zero/end values.

Fieldbus address (ADDRESS)

How to change the fieldbus slave address for proper device addressing.

Displaying a physical value

Explains the LCD display layout, including symbols, first line, and decimal point display.

Menu structure

Describes how to navigate the menu using the mode button and lists main menu items with their submenus.

Menu-controlled pressure transmitter programming

Details the functions and procedures for menu-driven programming via buttons.

Parameter description

Describes parameters like "VIEW", "GET 0%/100%", "SET 0%/100%", "SHIFT ZERO", "SHIFT OFFSET", "OUT 0%/100%".

ADDRESS parameter

Setting the fieldbus slave address for fieldbus transmitters.

Configuration with the PC;laptop or handheld terminal

Using DTM or handheld terminals for configuration, including connection diagrams.

Configuration with the graphical user interface (DTM)

System requirements and steps for starting the DTM software for configuration.

Correcting the zero shift; oblique sensor

Procedure for correcting zero shift using the DTM interface.

Explosion protection data

Potentially explosive atmospheres

Explosion protection data for intrinsically safe and flameproof transmitters, including temperature classes and supply limits.

Technical data

Functional specifications

Details measured variables, span limits, and zero suppression/elevation for 265Dx and 265Vx.

Operating limits

Temperature limits for operating, LCD display, seals, and storage.

Pressure limits

Overpressure limits for different sensor codes and transmitter types.

Environmental limits

Details EMC, Low Voltage, PED compliance, vibration, shock resistance, and protection types.

HART digital communication and 4... 20 mA output current

Electrical data for HART communication, including power supply, ripple, load, and LCD display options.

PROFIBUS PA output

Technical data for PROFIBUS PA output, including power supply, current consumption, and output signal.

FOUNDATION Fieldbus output

Technical data for FOUNDATION Fieldbus output, including power supply, current consumption, and output interface.

Measuring accuracy

Reference conditions, dynamic behavior, and measuring errors for differential pressure and absolute pressure sensors.

Operating influences 265 Dx

Thermal effects on zero signal and span, installation position, and long-term stability for 265Dx.

Operating influences 265 Vx

Thermal effects on zero signal and span, installation position, and long-term stability for 265Vx.

Technical specification

Details materials, connections, calibration, and optional accessories for the transmitter.

Mounting dimensions (not design data)

Diagram showing mounting dimensions for the differential pressure transmitter with barrel housing.

Differential pressure transmitter with DIN housing

Diagram showing mounting dimensions for the differential pressure transmitter with DIN housing.

Mounting options with bracket

Maintenance; Repair

Removal

Warnings and general risks before removing or disassembling the device.

Removing; Installing the process flange

Procedures for removing and installing the process flange, including cleaning and torque specifications.

Removing the electronics

Step-by-step instructions for removing the electronics housing and its components.

Appendix

Approvals and certifications

Details of CE mark and Ex symbols, indicating compliance with relevant directives.

Statement on the contamination of devices and components

Form for customers to declare contamination status before repair/maintenance.

Related product manuals