Electrical connection
32 265Dx, 265VS IM/265D/V-EN-02
Pos: 13.12 /Übers chriften/1.1/1-s paltig/M - O/Montage und Ansc hluss der Gerätesteck dose @ 1\mod_1147681492078_31 01.doc @ 11027
5.4 Assembling and connecting the socket connector
Pos: 13.13 /Elekt rischer Anschluss/ Druck/Druckmessumfor mer/Allgemein/M ontage und Anschluss der Ger ätesteckdose @ 1\mod_114768 1590765_3101.doc @ 11035
The socket connector for connecting the cable is supplied unassembled as an accessory for the
transmitter.
Important
Please observe the connection diagram included with the plug.
Assembly is depicted in the figure below.
1. The contacts (2) are crimped or soldered onto the cable ends (wire cross section of
0.75 … 1 mm
2
(AWG 18 … AWG 17)), from which approx. 1.5 … 2 cm (0.59 … 0.79 inch) of
the sleeve and approx. 8 mm (0.32 inch) of the insulation have been stripped; they are then
inserted into the socket (1) from the rear.
2. Slide the set screw (6), clamping ring (5), gasket (4), and housing (3) onto the cable in the
order indicated before assembly (you may have to adjust the gasket (4) to fit the cable
diameter).
Important
Before you press the contacts completely into the socket, check the connection points again.
Incorrectly inserted contacts can be removed by using a press-out tool (part no.: 0949 813), or
a standard ballpoint pen as a makeshift tool.
Fig. 11: Assembly of Han 8D (8U) socket connector
1 Socket
2 Contact
3 Housing
4 Gasket (can be cut)
5 Clamping ring
6 PG 11 set screw
7 Cable (diameter 5 … 11 mm
(0.20 ... 0.43 inch))
Pos: 13.14 /Elekt rischer Anschluss/ Druck/Druckmessumfor mer/Allgemein/Er dung @ 2\mod_1149834520203_310 1.doc @ 28813
Grounding
A terminal is available on both the outside of the housing and in the plug for grounding (PE) the
transmitter. Both terminals are electrically connected to one another.
Pos: 13.15 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830