EasyManua.ls Logo

ABB 2600T-264 User Manual

ABB 2600T-264
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ABB MEASUREMENT & ANALYTICS | OPERATING INSTRUCTION
266 with PROFIBUS PA Communication
Pressure transmitters
Engineered solutions for all
applications
Measurement made easy
Introduction
The 2600T family provides comprehensive range of
top quality pressure measurement products,
specifically designed to meet the widest range of
applications ranging from arduous conditions in
offshore oil and gas to the laboratory environment
of the pharmaceutical industry.
For more information
Further publications for 2600T series pressure
products are available for free download from
www.abb.com/pressure
266 models

Table of Contents

Questions and Answers:

ABB 2600T-264 Specifications

General IconGeneral
TypePressure Transmitter
Model2600T-264
Accuracy±0.075% of span
Operating Temperature-40 to 85°C (-40 to 185°F)
Measurement TypeDifferential Pressure
Output Signal4-20 mA, HART
Power Supply10.5 to 45 V DC
Process Connection1/2-14 NPT, M20 x 1.5
Electrical ConnectionM20x1.5, 1/2-14 NPT
Housing MaterialStainless steel
Diaphragm Material316L SST, Hastelloy C
Enclosure RatingIP66, NEMA 4X

Summary

Safety Guidelines for Pressure Transmitters

General Safety Information

Overview of safety aspects for device operation and manual adherence.

Safe Use and Personnel Requirements

Covers improper use, technical limits, qualified personnel, and essential safety practices.

Transport, Storage & Installation Safety

Safety for transport, storage, electrical installation, and inspection/maintenance.

Mounting Procedures

General Mounting Principles

Emphasizes careful study of instructions and checking device suitability for the measuring point.

Mounting the Transmitter

Covers factory configuration and hazardous area considerations for mounting.

DP Transmitter Mounting

Guidance on mounting DP transmitters, including bracket use and vertical orientation.

P Style Transmitter Mounting

Guidance on mounting P-style transmitters, emphasizing vertical orientation.

Impulse Piping Connection

Guidelines for laying impulse piping, including length, bends, and filling.

Process Connections

Details on process connection sizes, centers, and flange adapter installations.

Installation Recommendations

Piping configurations for various applications like steam, gas, liquid level, and tank pressure.

Device Introduction and Wiring

Transmitter Wiring

Warnings and guidelines for electrical connections, cable entry, PROFIBUS wiring, and grounding.

PROFIBUS Electronics and Local Controls

On-Board Switches

Details the function of the three on-board switches (SW1, SW2, SW3).

Local Push Button Operations

Explains using Zero, Span, and Write Protection buttons, including SW3 effects.

HMI Local Indicator

Commissioning Procedures

Device Operations

PILD Algorithm for Impulse Line Detection

Maintenance Procedures

Hazardous Area Considerations

Appendices: Device Information and Support

Related product manuals