Technical data
IM/265D/V-EN-02 265Dx, 265VS 71
Pos: 23.32 /Übers chriften/1.1.1/1-s paltig/PROFIBUS PA-Ausgang @ 5\mod_1165392154421 _3101.doc @ 50337
10.4.2 PROFIBUS PA output
Pos: 23.33 /==== Wec hsel ein- auf zweispalti g ==== @ 0\mod_1130421847171_310 1.doc @ 3828
Change from one to two colu mns
Pos: 23.34 /Tec hnische Daten / Datenblatt/Druck/Druckmessumformer/265Dx, 265Vx/PROFI BUS PA-Ausgang @ 5\mod_11641887605 46_3101.doc @ 49270
Model
Pressure transmitter conforming to Profile 3.0, Class A and B;
ID number 04C2 HEX
Power supply
The transmitter is operated at 10.2 … 32 VDC (no polarity).
The supply voltage must not exceed 17.5 VDC when used in EEx ia
zones.
Intrinsically safe installation in accordance with FISCO model.
Current consumption
Operating (quiescent): 11.7 mA
Fault current limit value: Maximum 17.3 mA
Output signal
Physical layer in accordance with IEC 1158-2/EN 61158-2;
transmission using Manchester II modulation at 31.25 kbit/sec.
Output interface
PROFIBUS PA communication according to Profibus DP50170 Part
2/DIN 19245 Part 1-3
Output cycle time
40 ms
Function blocks
265Dx: 2 standard analog input function blocks
265Vx: 1 standard analog input function block
1 transducer block
1 physical block
LCD display (optional)
19-segment alphanumeric display (two lines, six characters) with
additional bar chart display; option of backlighting.
Customized display:
Output value in percent or OUT (analog input)
Diagnostic messages, alarms, measuring range upper limit violations,
and changes to the configuration are also displayed.
Transmitter interference mode
Permanent self-diagnosis; potential errors indicated in diagnostic
parameters and in the status of process values.
Pos: 23.35 /==== Wec hsel zwei- auf einspalti g ==== @ 0\mod_1130421955859_310 1.doc @ 3829
Change from one to two colu mns
Pos: 23.36 /==== Leeres Modul mit zwei Absatz marken, DS, 1-spaltig ==== @ 3\mod_1159257408468_0.doc @ 42813
Pos: 23.37 /Überschriften/1.1.1/ 1-spaltig/FOUNDATION-Fieldbus-Aus gang @ 5\mod_1165392250328_3101. doc @ 50358
10.4.3 FOUNDATION Fieldbus output
Pos: 23.38 /==== Wec hsel ein- auf zweispalti g ==== @ 0\mod_1130421847171_310 1.doc @ 3828
Change from one to two colu mns
Pos: 23.39 /Tec hnische Daten / Datenblatt/Druck/Druckmessumformer/265Dx, 265Vx/FOUNDATION Fiel dbus-Ausgang @ 5\mod_116418 8958671_3101.doc @ 49291
Power supply
The transmitter is operated at 10.2 … 32 VDC (no polarity).
The supply voltage must not exceed 17.5 VDC when used in EEx ia
zones.
Intrinsically safe installation in accordance with FISCO model.
Current consumption
Operating (quiescent): 11.7 mA
Fault current limit value: Maximum 17.3 mA
Output signal
Physical layer in accordance with IEC 1158-2/EN 61158-2;
transmission using Manchester II modulation at 31.25 kbit/sec.
Function blocks/execution time
265Dx: 2 standard analog input function blocks/maximum 25 ms
265Vx: 1 standard analog input function block/maximum 25 ms
1 standard PID function block
Additional blocks
1 manufacturer-specific pressure with calibration transducer block
1 enhanced resource block
Number of link objects
10
Number of VCRs
16
Output interface
FOUNDATION Fieldbus digital communication protocol in
accordance with standard H1; complies with specification V. 1.5.
FF registration no.: IT023600
LCD display (optional)
19-segment alphanumeric display (two lines, six characters) with
additional bar chart display; option of backlighting.
Customized display:
Output value in percent or OUT (analog input)
Diagnostic messages, alarms, measuring range upper limit violations,
and changes to the configuration are also displayed.
Transmitter interference mode
Permanent self-diagnosis; potential errors indicated in diagnostic
parameters and in the status of process values.