Use in explosion-proof areas   
18 265Dx, 265VS IM/265D/V-EN-02 
 
Pos: 7.16 /Übersc hriften/1.1/1-spal tig/V - Z/Zündschut zart Eigensicherhei t, druckfeste Kapselung und ener giebegrenzte Bet riebsmittel @ 3\mod_1157 964815781_3101.doc  @ 41176 
 
2.6  Explosion protection types "Intrinsically safe", "Flameproof enclosure", and "Limited energy 
equipment" 
 
Pos: 7.17 /Ex-tec hnische Sicherheits hinweise/Druck/ Druckmessumformer/Al lgemein/Zündschutz art Eigensicherheit , druckfeste Kapsel ung und energiebegrenzte Bet riebsmittel @ 3\m od_1157963542656_3101.doc  @ 41071 
 
Alternative certification: 
•  Intrinsically safe      (Category 1/2, EEx i) or 
•  Flameproof enclosure    (Category 1/2, EEx d), or 
•  Limited energy equipment  (Category 3, EEx nL) 
 
 
Important 
Prior to commissioning, the selected type of explosion protection (only one may be selected) 
must be permanently marked in the appropriate box on the name plate. Once selected, the 
type of explosion protection may not be changed. 
 
If a supply is not intrinsically safe, or the transmitter has been fed in a way that is not intrinsically 
safe, the explosion protection type "Intrinsically safe" is no longer valid. 
 
 
Caution - Risk 
Failure to observe this information will have an adverse effect on explosion protection. 
 
Appropriate cable and wire entries must be used depending on the explosion protection type 
selected: 
 
Explosion protection type  Cable gland 
(minimum requirement) 
II 1/2 G EEx i 
II 1/2 D EEx i 
IP 54 
IP 6x 
II 1/2 G EEx d 
II 1/2 D EEx d 
EEx d 
EEx d and IP 6x 
II 3 G EEx n 
II 3 D EEx n 
EEx e 
EEx e and IP 6x 
 
Pos: 7.18 /Übersc hriften/1.1/1-spal tig/J - L/Kanadischer  Standard CSA - explosion pr oof @ 3\mod_1157964979734_31 01.doc @ 41197 
 
2.7  Canadian Standards Association (CSA): "Explosion-proof"  
 
Pos: 7.19 /Ex-tec hnische Sicherheits hinweise/Druck/ Druckmessumformer/Al lgemein/Kanadischer  Standard CSA - explosion pr oof @ 3\mod_1157963634125_ 3101.doc @ 41092 
 
 
 
Caution - Potential damage to parts 
Transmitters with LCD displays must not be used in etherized atmospheres. 
 
Pos: 7.20 /=======  Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830