EasyManua.ls Logo

ABB TTF300 - Intrinsic Safety Ex ia IIC Data (Part 2); Flameproof Ex db IIC Protection Data; Dust Explosion Protection Data; Intrinsic Safety Ex ia IIC Data (Part 3)

ABB TTF300
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
CI/TTF300-EN TTF300 EN - 7
1.4.4 Name plate: TTF300 - PROFIBUS PA / FOUNDATION Fieldbus
The name plate is located on the transmitter housing.
A00266
TTF300
PTB 09 ATEX 2016 X
II1GExia IICT6
II 2(1) G Ex [ia]ib IIC T6
II 2G (1D) Ex [iaD]ib IIC T6
T1...T4 Ta. = -40 °C ... +60 °C (Zone 0) ... +85 °C (Zone 1)
T5 Ta. =
T6 Ta. =
TTF300-E1P;
TTF300-E1F; PTB 09 ATEX 2016 X
-40 °C ... +56 °C (Zone 0) ... +71 °C (Zone 1)
-40 °C ... +44 °C (Zone 0) ... +56 °C (Zone 1)
Automation Products GmbH
Alzenau Germany 2009
TTF300
U = + 9...32 V, I = 12 mA, FISCO
IDENT 3470 [9700], PA-3.01
Ta. = -40°C...+85°C
Sa
O-Code: TTF300-E1P
2400034561
Ser.-No: 2064388
HW. Rev. 1.00
SW. Rev. 1.00.00
IP20
13
14
8
4
7
5
3
2
12
6
1
15
Automation Products GmbH
Alzenau Germany 2009
TTF300
U = + 9...32 V, I = 12 mA, FISCO
DEVICE_ID 0003200125, ITK - 5.1
Ta. = -40°C...+85°C
Sa
O-Code: TTF300-E1F
2400021437
Ser.-No: 2064567
HW. Rev. 1.00
SW. Rev. 1.00.00
IP20
13
14
8
4
7
5
3
2
12
6
1
15
10
11
9
Fig. 2: Example for ATEX explosion protection
1 Project number
2 Manufacturer of transmitter
3 Country and year of manufacture
4 Order number
5 Serial number
6 Supply voltage range, typical current
range, concept for intrinsically safe
fieldbuses
7 PROFIBUS ID number, protocol /
FOUNDATION Fieldbus device ID
number
8 Ambient temperature range / housing
degree of protection
9 Ex mark (optional)
10Protection class of hazardous area
design (optional)
11Temperature class of hazardous area
design (optional)
12Refer to product documentation
13Software revision number / hardware
revision number
14CE mark (EC conformity)
15Type designation
1.5 Transport safety information
Observe the following information:
Do not expose the device to moisture during transport. Pack the device accordingly.
Pack the device so that it is protected from vibration during transport, e.g. through air-
cushioned packaging.