EasyManua.ls Logo

ABB VA Master FAM540 Series - Page 18

ABB VA Master FAM540 Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 VA Master FAM540 METAL CONE VARIABLE AREA FLOWMETER | OI/FAM540-EN REV. E
… 2 Use in potentially explosive atmospheres in accordance with ATEX and IECEx
… Safety specifications ATEX / IECEx
Table 4: Analoganzeiger mit Grenzsignalgeber
Model FAM54xB/C/Dx
Type of protection: non-sparking materials, dust explosion protection.
Order
code
*
Marking Terminals Electrical values T
amb
20 °C to (50 °C to )
Temp. class
T
medium
Maximum
Insulation
A4, A9, B1 ATEX:
II 1/3 G Ex ec h IIC T6 ... T1 Ga/Gc
II 2D Ex h tb IIIC T85°C ... Tmedium Db
IECEx:
Ex ec h IIC T6 ... T1 Ga/Gc
Ex h tb IIIC T85°C ... Tmedium Db
41 / 42
**
51 / 52
**
U
max
= 16 V
I
max
= 25 mA
P
max
= 64 mW
40 °C T1
440 °C No
40 °C T1
375 °C yes
40 °C T1
260 °C yes
50 °C T1
300 °C yes
50 °C T2
290 °C yes
50 °C T2
220°C yes
60 °C T2
320 °C No
60 °C T2
230 °C yes
60 °C T3
170 °C yes
70 °C T3
195 °C No
70 °C T3
150 °C yes
70 °C T4
130 °C yes
70 °C T5
95 °C yes
60 °C T6
80 °C yes
41 / 42
**
51 / 52
**
U
max
= 16 V
I
max
= 52 mA
P
max
= 169 mW
40 °C T1
440 °C No
40 °C T1
375 °C yes
40 °C T1
260 °C yes
50 °C T1
300 °C yes
50 °C T2
290 °C yes
50 °C T2
220°C yes
60 °C T2
320 °C No
60 °C T2
230 °C yes
60 °C T3
170 °C yes
70 °C T3
195 °C No
70 °C T3
150 °C yes
70 °C T4
130 °C yes
60 °C T5
60 °C yes
50 °C T5
90 °C No
40 °C T6
60 °C yes
A4, A9, B1 ATEX:
II 1/3 G Ex ec h IIC T6 ... T1 Ga/Gc
II 2 D Ex h tb IIIC T85°C ... Tmedium Db
IECEx:
Ex ec h IIC T6 ... T1 Ga/Gc
Ex h tb IIIC T85°C ... Tmedium Db
41 / 42
**
51 / 52
**
Umax= 16 V
Imax = 76 mA
Pmax = 242 mW
40 °C T1
440 °C No
40 °C T1
310 °C yes
40 °C T2
190 °C yes
50 °C T2
340 °C No
50 °C T2
230 °C yes
60 °C T2
230°C No
60 °C T3
160 °C yes
70 °C T4
120 °C No
70 °C T4
100 °C yes
40 °C T5
60 °C yes
30 °C T6
30 °C yes
* Order code ‘Explosion protection and approvals’ (versions 9, 10); refer to Ordering information in the data sheet on page 62.
** for connection to a non-intrinsically safe circuit If the device is to be operated subsequently with type of protection "intrinsically safe", then U
max
= 60 V may
not be exceeded.

Table of Contents