58 VA Master FAM540 METAL CONE VARIABLE AREA FLOWMETER | OI/FAM540-EN REV. E
11 Maintenance
Safety instructions
DANGER
Danger of explosion if the device is operated with the
transmitter housing open!
Before opening the transmitter housing, bear in mind the
following:
A valid fire permit must be present.
Make sure that there is no explosion hazard.
Switch off the power supply and wait for t > 2 minutes
before opening.
WARNING
Risk of injury due to live parts!
When the housing is open, contact protection is not provided
and EMC protection is limited.
Before opening the housing, switch off the power supply.
CAUTION
Risk of burns due to hot measuring media
The device surface temperature may exceed 70 °C (158 °F),
depending on the measuring medium temperature!
Before starting work on the device, make sure that it has
cooled sufficiently.
NOTICE
Damage to components!
The electronic components of the printed circuit board can be
damaged by static electricity (observe ESD guidelines).
Make sure that the static electricity in your body is
discharged before touching electronic components.
Repair and maintenance activities may only be performed by
authorized customer service personnel.
When replacing or repairing individual components, use original
spare parts.
Corrective maintenance work may only be performed by trained
personnel.
Before removing the device, depressurize it along with any
adjacent lines or vessels.
Check whether hazardous materials have been used as
measuring medium before opening the device. Residual
amounts of hazardous material may still be present in the
device and could escape when it is opened.
Within the scope of operator responsibility, check the following
as part of a regular inspection:
pressure-carrying walls / pressure equipment liner
the measurement-related function
the leak tightness
• the wear (corrosion)
Cleaning
When cleaning the exterior of meters, make sure that the
cleaning agent used does not corrode the housing surface and
the seals.
To avoid static charge, a damp cloth must be used for cleaning.
Sensor
Essentially no maintenance is required for the sensor.
The following items should be checked annually:
Ambient conditions (air circulation, humidity).
Tightness of the process connections,
Cable entries and cover screws,
Operational reliability of the power supply, lightning
protection, and station ground.