VA Master FAM540 METAL CONE VARIABLE AREA FLOWMETER | OI/FAM540-EN REV. E 27
Safety specifications FM, cCSAus
Table 1: Analog indicator with alarm signaling unit (temperature data for FM in °F, for cCSAus in °C)
Order
code*
Marking Terminals
Electrical
values
T
amb
58 °F to
T
amb
50 °C to
Temp. class T
medium
Maximum
Insulation
F3, F4 FM
IS / CL I,II,III / DIV 1 / GP ABCDEFG /
T6 ... T1
**
DIP / CL II, III / DIV 1 / GP EFG / T6 ... T1
CL I, ZN 1 AEx ia IIC T6 ... T1
cCSAus
IS / CL I,II,III / DIV 1 / GP ABCDEFG /
T6 ... T1
**
DIP / CL II, III / DIV 1 / GP EFG / T6 ... T1
Ex ia IIC T6 ... T1
DIP A21 TA 85°C to T
medium
41 / 42
***
51 / 52
***
U
i
= 16 V
I
i
= 25 mA
P
i
= 64 mW
C
i
= 50 nF
L
i
= 250 µH
104 °F 40 °C T1 824 °F 440 °C No
104 °F 40 °C T1 707 °F 375 °C yes
104 °F 40 °C T1 500 °F 260 °C yes
122 °F 50 °C T1 572 °F 300 °C yes
122 °F 50 °C T2 554 °F 290 °C yes
122 °F 50 °C T2 428 °F 220°C yes
140 °F 60 °C T2 608 °F 320 °C No
140 °F 60 °C T2 446 °F 230 °C yes
140 °F 60 °C T3 338 °F 170 °C yes
158 °F 70 °C T3 383 °F 195 °C No
158 °F 70 °C T3 302 °F 150 °C yes
158 °F 70 °C T4 266 °F 130 °C yes
158 °F 70 °C T5 203 °F 95 °C yes
140 °F 60 °C T6 176 °F 80 °C yes
41 / 42
***
51 / 52
***
U
i
= 16 V
I
i
= 52 mA
P
i
= 169 mW
C
i
= 50 nF
L
i
= 250 µH
104 °F 40 °C T1 824 °F 440 °C No
104 °F 40 °C T1 707 °F 375 °C yes
104 °F 40 °C T1 500 °F 260 °C yes
122 °F 50 °C T1 572 °F 300 °C yes
122 °F 50 °C T2 554 °F 290 °C yes
122 °F 50 °C T2 428°F 220°C yes
140 °F 60 °C T2 608 °F 320 °C No
140 °F 60 °C T2 446 °F 230 °C yes
140 °F 60 °C T3 338 °F 170 °C yes
158 °F 70 °C T3 383 °F 195 °C No
158 °F 70 °C T3 302 °F 150 °C yes
158 °F 70 °C T4 266 °F 130 °C yes
140 °F 60 °C T5 140 °F 60 °C yes
122 °F 50 °C T5 194 °F 90 °C No
104 °F 40 °C T6 140 °F 60 °C yes
41 / 42
***
51 / 52
***
U
i
= 16 V
I
i
= 76 mA
P
i
= 242 mW
C
i
= 50 nF
L
i
= 250 µH
104 °F 40 °C T1 824 °F 440°C No
104 °F 40 °C T1 590 °F 310 °C yes
104 °F 40 °C T2 374 °F 190 °C yes
122 °F 50 °C T2 644 °F 340 °C No
122 °F 50 °C T2 446 °F 230 °C yes
140 °F 60 °C T2 446 °F 230 °C No
140 °F 60 °C T3 320 °F 160 °C yes
158 °F 70 °C T4 248 °F 120 °C No
158 °F 70 °C T4 212 °F 100 °C yes
104 °F 40 °C T5 140 °F 60 °C yes
86 °F 30 °C T6 86 °F 30 °C yes
* Order code ‘Explosion protection and approvals’ (versions 9, 10); refer to Ordering information in the data sheet on page 62.
** ‘IS’ installation in accordance with Installation Drawing SDM-10-A0253.
*** for connection to an intrinsically safe circuit