VA Master FAM540 METAL CONE VARIABLE AREA FLOWMETER | OI/FAM540-EN REV. E 9
Model FAM54xE/Fx (analog indicator with transmitter and with or without LCD indicator)
Marking Type of protection Order code* Limit value table
ATEX II 1/2 G Ex h ia IIC T4 ... T1 Ga/Gb Intrinsically Safe A4 Table 1 on page 14
II 1/3 G Ex ec h ic T6 ... T1Ga/Gc Non-sparking materials
II 2 D Ex h tb IIIC T85°C ... Tmedium Db Dust explosion protection
IECEx Ex h ia IIC T4 ... T1 Ga/Gb Intrinsically Safe
Ex ec h ic IIC T6 ... T1Ga/Gc Non-sparking materials
Ex h tb IIIC T85°C ... Tmedium Db Dust explosion protection
ATEX II 1/2 G Ex db h IIC T6 ... T1 Ga/Gb Flameproof / Explosion-Proof A9 Table 1 on page 14
II 1/2 G Ex h ia IIC T4 ... T1 Ga/Gb Intrinsically Safe
II 1/3 G Ex ec h ic IIC T6 ... T1 Ga/Gc Non-sparking materials
II 2 D Ex h tb IIIC T85°C ... Tmedium Db Dust explosion protection
IECEx Ex db h IIC T6 ... T1 Ga/Gb Flameproof / Explosion-Proof
Ex h ia IIC T4 ... T1 Ga/Gb Intrinsically Safe
Ex ec h ic IIC T6 ... T1 Ga/Gc Non-sparking materials
Ex h tb IIIC T85°C ... Tmedium Db Dust explosion protection
ATEX II 1/3 G Ex ec h ic IIC T6 ... T1 Ga/Gc Non-sparking materials B1 Table 4 on page 18
II 2 D Ex h tb IIIC T85°C ... Tmedium Db Dust explosion protection
IECEx Ex ec h ic IIC T6 ... T1 Ga/Gc Non-sparking materials
Ex h tb IIIC T85°C ... Tmedium Db Dust explosion protection
* Order code ‘Explosion protection and approvals’ (versions 9, 10); refer to Ordering information in the data sheet on page 62.
Change from one to tw o columns