Operation Manual / 4 Product description / A100-L
5 Operation and service / 5.2 Service work
© Copyright 2018 ABB. All rights reserved. HZTL4034_EN Revision N November 2018
5.2.6 Entries in the engine logbook
The monitoring of the engine system enables conclusions to be drawn on the behaviour of
the turbocharger.
The following operating data and measured values must be entered regularly into the engine
logbook of the enginebuilder:
¡ Performance and speed of the engine
¡ Speed of the turbocharger
¡ Air intake temperature
¡ Exhaust gas temperature before and after the turbine
¡ Pressure of the charge air
¡ Pressure loss in the charge air cooler
¡ Lubricating oil pressure and lubricating oil temperature
¡ Pressure loss in the filter silencer
¡ Air temperature after the charge air cooler
If present:
¡ Air temperature after the compressor
Page 26 / 110