American Beer Equipment 2001 SW 6
th
St.
Lincoln, NE 68522
8
bubble could set the probe off). If the nozzle time is too long, the nozzle will
remain open for longer than needed and stay in the can.
b. Nozzle offset compensates for nozzles which fill faster or slower than the
average nozzle. If an individual nozzle is too quick or slow, alter the nozzle’s
time setting accordingly.
E. C0
2
Pulse can be turned off or on via the time setting screen.
a. Typically, a small jet (around .020 seconds) provides the correct amount of extra
CO
2
, 3/4
th
of the way up the can to promote an extra layer of foam. This foam
will allow lids to lie atop the foamy head and prevent dissolved oxygen pickup
(DO
2
).
Figure 2. Time Settings Screen on HMI