30
CONNECTION EXAMPLES
15
16
1
2
8
9
15
16
1
2
8
9
8
9
8
9
1
2
9
8
1
2
Radar
Radar
Remember sequence control jumpers
Note!
Disconnect mains supply
and remove the battery
cable before making
any connections!
Tandem doors;
stepwise opening
- The example is for tandem
doors with two-way traffic.
- The opening steps can be
adjusted according to the
traffic direction.
- The first door in the traffic
direction opens first, the
second after a preset
delay (adjustment point 4).
- The open time is adjusted
separately for the two
doors (adjustment point 7).
- The door opening sequence
is adjustable to meet the
customer's requirement's.
OUTWARD
INWARD
Door operator 1:
inward traffic
- outer door opens
first
- inner door's delay
adjusted on door
operator 2
Door operator 2:
outward traffic
- inner door opens
first
- outer door's delay
adjusted on door
operator 1
NOTE! Use
direction-sensitive
micro-wave radars
or mechanical
pulse
NOTE! Use pair twisted, shielded cable
NOTE! The inside impulse is not in operation!
Double doors:
1) Square-edged doors
- With this connection both doors open
simultaneously.
The passive door closes first.
Active door Passive door
Active door Passive door
Open time 0-60 s
(adjustment point 7)
Open time 0-60 s
(adjustment point 7)
Open time 1-2 s
shorter than for
active door
Open time 1-2 s
shorter than for active
doorAdjust delay 0-5 s
(adjustment point 4)
2) Rebated doors
- With this connection the active
door opens first.
The passive door closes first.

Other manuals for Abloy DA400