29
PROGRAMMING HANDSET
OK
OK
ABLOY
OK
ABLOY
O
K
Control values
Change
Control point
Decrease
Power switch
Increase
Set value
Reset error
4-Digit
Display
Transmitter
1. Switch power ON
2. Enter master code and press
2. Find control point and adjust value
3. Press
Errors:
ERR 1: Wrong master code
ERR 2: Communication error
ERR 3: Value was not saved
Factory settings; press both buttons
for 2 seconds (until FCLr-text diappears)
(Settings are available until power has been switched OFF/ON)
Aim to the
LED's
9V Battery
(Lithium or Alkaline)
Master code is 0000.
Power is switched off automatically after 10 minutes (idle state).
Use power switch to save batteries!!