31
CONNECTIONS WITH ABLOY ELECTRIC LOCKS
NOTE!
Before connections
switch the power off
and remove battery.
Note! Make sure you choose the correct
lock case for fire doors and exit doors.
1)
- the impulse device opens
both the lock and the door.
- the door operator receives the
locking circuit information from the
microswitch in the lock case.
- the latch in the 8380 lock will not
tolerate any side load when the
door is closed. To counteract this
situation adjust control point 21
to enable to drive the door closed
for 0.4 seconds allowing the
latch freedom of movement
- ABLOY lead cover 8810 or
8811 should always be used for
swing door situations.
ABLOY Electric lock 8380,
solenoid lock case
2)
- the impulse device opens
both the lock and the door.
- the door operator receives the
locking circuit information from the
micro switched keep ABLOY 8400.
- ABLOY lead cover 8810 or
8811 should always be used for
swing door situations.
Motor locks 8329,
8904, 8910
18
16
15/17
13
12
11
10
18
15/17
13
12
11
10
9
8
Strike
plate with
indicator
red
red
white
green
green
blue
blue
black
black
SCANDINAVIAN RANGE
DA400
DA400
12 VDC
24 VDC
PLEASE!
Check the right
voltage from the
lock case.
red